SPECIAL MEASUREMENTS IN WASTE INCINERATION PLANTS WITH GRATE TYPE BOILERS

The article discusses the problems of special measurements in installations for thermal waste transformation, with particular emphasis on temperature measurements using the HVT (High Velocity Thermocouple) and flue gas speed probes. The measurements of temperature and velocity of fumes in waste boilers made constitute important information for producers and users of waste incineration plants in the context of meeting normative requirements, i.e. residence time of at least 2 seconds in the high temperature zone (above 850⁰C)